Disjoncteur différentiel RCBO SVL1E-63

RCBO SVL1E-63(images 1)

Specification:

Electrical Features
ModeElectronic
TypeA
Rated Current In16, 20, 25, 32, 40, 50, 63A
Poles2P(1P+N), 4P(3P+N)
Rated Voltage Ue2P 240V~, 4P 415V~
Insulation Voltage Ui500V
Rated Frequency50/60Hz
Rated Residual Operation Current (In)30mA
Rated Residual Operating Current (Idc)6mA
Rated Breaking Capacity10000A
Break Time Under In≤0.1s
Rated Impulse Withstand Voltage (1.5/50) Uimp4000V
Dielectric Test Voltage at ind.Freq. for 1min2kV
Pollution Degree2
Thermo-magnetic Release CharacteristicB, C
Electrical Life4000 Cycles
Mechanical Life10000 Cycles
 
Installation
Contact Position IndicatorYes
Protection DegreeIP20
Reference Temperature for Setting of thermal element30℃
Ambient Temperature (with daily average≤35)-25℃~+40℃
Storage Temperature-25℃~+70℃
Terminal Connection TypeCable/Pin-type Busbar/U-type Busbar
Terminal Size top/bottom for Cable25mm2  18~3AWG
Terminal Size top/bottom for Busbar25mm2  18~3AWG
Tightening Torque2.5Nm  22In-lbs
MountingOn DIN Rail EN60715(35mm) by means of fast clip device
ConnectionFrom top

Tripping Current Range:

Lagging AngleI△n>0.01AI△n≤0.01A
0.35I△n ≤ I△ ≤ 1.4I△n0.35I△n ≤ I△ ≤ 2I△n
90°0.25I△n ≤ I△ ≤ 1.4I△n0.25I△n ≤ I△ ≤ 2I△n
135°0.11I△n ≤ I△ ≤ 1.4I△n0.11I△n ≤ I△ ≤ 2I△n
 
Alternative Current SensitivePulsating Direct Current SensitiveSurge Current Proof
B Class
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual current, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
RCBO SVL1E-63(images 2)
They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.
RCBO SVL1E-63(images 3)
RCCB’s surge capacity. Not tripping at standardized 8/20 us surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

Circuit Diagram Overall and Installation Dimension (mm)

RCBO SVL1E-63(images 4)

SUIVANT :

Recommandations connexes

  • Disjoncteur à boîtier moulé UL489 NDM3EU-225

    1302

    NDM3EU-225 is Electronic Mold Case Circuit Breaker which is satisfied UL489。The product is developed for the North America market demand,and it meets the UL489 standard molded case circuit breaker product.The rated insulation voltage of the produ...

    Voir les détails
  • Norme IEC 60947-2 UL 489 NDB2T-63 3P

    1265

    NDB2T-63 (UL489) destiné aux réseaux de distribution électrique basse tension dans les secteurs de l'industrie, du bâtiment, de l'énergie, des télécommunications et des infrastructures.

    Voir les détails
  • Disjoncteur à boîtier moulé NDM5-1600H

    1149

    The NDM5-1600 series of moulded case circuit breakers (referred to as circuit breakers) have a rated insulation voltage of 1000V and apply to circuits with the AC 50Hz/60Hz, the rated working voltageAC380/400/415V、AC500V、AC660/690V、AC800V,Va...

    Voir les détails
  • Disjoncteur à boîtier moulé NDM3A-630

    989

    The NDM3A-630 molded case circuit breaker (hereinafter referred to as circuit breaker) appliesto infrequent switching of circuits with the AC 50/60Hz, the working voltage of AC1000V and working current of 630A as well as infrequent motor startin...

    Voir les détails
En savoir plus !

Liste des produits disponibles
Liste des produits disponibles Envoyer une demande de renseignements sur les produits ci-dessus