SVM5H-400H/R MCCB 1 000 V CA

SVM5H-400H/R  1000VAC MCCB(images 1)

Gemeral

SVM5H series of moulded case circuit breaker is supplied with rated insulating voltage 1150V and used for circuit of A.C. 50Hz, rated operating voltage AC 1140V. (or below), rated operating current up to 630A for infrequent changing over and starting of the motors.

Products are widely used in new energy, photovoltaic (string type), electric power, industrial control, real estate, power supply, telecommunications, rail transit and other industries.

Equiped with the protection devices for over-current, short circuit and u ndervoltage, the products are capable of preventing damage of circuits and supply units. The products conforms to GB/T14048.2, IEC60947-2 stardands.

Normal Operating Conditions                                            

Altitude: ≤2000m  

Installation height 2000m ~ 5000m can be specially customized. The product needs to reduce the capacity to use.

Pollution Degree: 3 according to IEC 60947-1

Ambient Temp. (operating): -5 to 40 ℃

For the working conditions of -40~-5℃ ambient temperature, please inform us when ordering.

When the ambient temperature is higher than 40 ° C, the product should be used at reduced capacity.

Ambient Temp. (storage): -40 to 70 ℃

The average ambient temp. in 24 hours cannot exceed 35 ℃.

The relative humidity cannot exceed 50% @+40 ℃. A lower temperature can have a higher humidity. The relative humidity can reach 90% at 20 ℃, and corresponding measures should be taken for the condensation frost caused by the temperature change.

Model Description of MCCB

SVM5H-400H/R  1000VAC MCCB(images 2)

Characteristics                                                            

Poles3P
Frequency50 Hz
Rated Current (In)250, 280, 315, 320, 350, 400
Rated Insulation Voltage Vi1150 V AC
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage (Ue)AC415VAC500/550 /690/600VAC800VAC1000 /1140V
Breaking Capacity CodeHRHRHRHR
Limiting Short-circuit Breaking Capacity Icu85100506036.5501015
Operating Short-circuit Breaking Capacity Ics85100506036.5501015
Mechanical Life10000 cycles
Electrical Life1000 cycles1000 cycles1000 cycles700 cycles
Ambient Temperature-35℃~+70℃
AccessoryShunt release, auxiliary device, alarm device, manual operating mechanism, electric operating mechanism
Dimensions (L*W*H)250*182*165mm
LAST : SUIVANT :

Recommandations connexes

  • NDB1T-63 MCB miniature circuit breaker

    1272

    Application ●Short -circuit protection ●Over-load protection ●Isolation NDB1T-63 dedicated to the low voltage power distribution system of industrial, buildings, energy communications and infrastructure. Specification: 1P+N:AC230/240V; 2P:AC400...

    Voir les détails
  • Norme IEC 60947-2 UL 489 NDB2T-63 3P

    1265

    NDB2T-63 (UL489) destiné aux réseaux de distribution électrique basse tension dans les secteurs de l'industrie, du bâtiment, de l'énergie, des télécommunications et des infrastructures.

    Voir les détails
  • Disjoncteur à boîtier moulé NDM3A-630

    989

    The NDM3A-630 molded case circuit breaker (hereinafter referred to as circuit breaker) appliesto infrequent switching of circuits with the AC 50/60Hz, the working voltage of AC1000V and working current of 630A as well as infrequent motor startin...

    Voir les détails
  • NDM2(X)-125

    1278

    1. Applicable Scope and Purpose of Circuit Breaker The NDM2(X)-125 molded case circuit breaker (hereinafter referred to as circuit breaker) applies to infrequent switching of circuits with the AC 50/60Hz, the working voltage of AC690V and workin...

    Voir les détails
En savoir plus !

Liste des produits disponibles
Liste des produits disponibles Envoyer une demande de renseignements sur les produits ci-dessus